Item Number |
OBSERVATIONS AND CORRECTIVE ACTIONS |
14B
|
Violation of Code: [511-6-1.05(10)(e)1,2,4] Observed a cardboard box of towels being stored on the floor underneath a table. Observed cardboard boxes of an end table and toxic chemicals being stored on the floor in a back room. Except as specified in paragraph 4 of this subsection, cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored: (i) In a clean, dry location; (ii) Where they are not exposed to splash, dust, or other contamination; and (iii) At least 6 inches (15 centimeters) above the floor. PIC moved the boxes. Corrected On-Site. New Violation.
|
15A
|
Violation of Code: [511-6-1.05(6)(a)] Observed a broken door to dry storage in the front service area. Equipment components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications. PIC shall have the door repaired. New Violation. Correct By: 03/30/2024
|
15A
|
Violation of Code: [511-6-1.05(6)(a)] Observed a reach in cooler in the front service area being held above 41F(46F). PIC had TCS food discarded stored in the reach in cooler discarded. Equipment shall be maintained in a state of repair and condition that meets the requirements. PIC shall have the reach in cooler repaired. New Violation.
|
15C
|
Violation of Code: [511-6-1.05(7)(d)] Observed heavy buildup of food and debris in the reach in cooler/freezer walls, shelving, and doors in a back storage room. Observed buildup on the shelving above the panini press in the front service area. Nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues. PIC shall have the non food contact surfaces cleaned. New Violation. Correct By: 03/23/2024
|
16A
|
Violation of Code: [511-6-1.06(1)(g),(h)] Observed hand sinks, prep sinks, three compartment sink failing to reach a minimum of 100/110F (79/80F). Hot water generation and distribution systems shall be sufficient to meet the peak hot water demands throughout the food service establishment. Pf PIC shall temporary close until hot water is restored to the facility. New Violation. Correct By: 03/30/2024
|
16B
|
Violation of Code: [511-6-1.06(2)(r)] Observed loose faucets on sinks in the front service area. A plumbing system shall be repaired according to law; P and maintained in good repair. PIC shall have the faucets repaired. New Violation. Correct By: 03/30/2024
|
17C
|
Violation of Code: [511-6-1.07(5)(a),(b)] Observed a ceiling tile missing in the back room. All physical facilities shall be maintained in good repair. PIC shall have the ceiling tile installed. New Violation. Correct By: 03/30/2024
|
17C
|
Violation of Code: [511-6-1.07(5)(a),(b)] Observed food and debris buildup on the walls and floor underneath equipment in the front service area and back rooms. Physical facilities shall be cleaned at a frequency to preclude accumulation. PIC shall have the physical facilities cleaned. New Violation. Correct By: 03/30/2024
|
17C
|
Violation of Code: [511-6-1.07(5)(f)] Observed the mop head being stored in the wringer of a mop bucket near the mop sink. After use, mops shall be placed in a position that allows them to air-dry without soiling walls, equipment, or supplies. PIC had the mop head stored to air dry. Corrected On-Site. New Violation.
|
17C
|
Violation of Code: [511-6-1.07(2)(a)] Observed porous ceiling tiles in a storage area. Except as specified under subsection (2)(d) of this Rule and except for antislip floor coverings or applications that may be used for safety reasons, floors, floor coverings, walls, wall coverings, and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. PIC shall have ceiling tiles replaced. New Violation. Correct By: 03/30/2024
|
18
|
Violation of Code: [511-6-1.07(5)(k)] Observed a cardboard box underneath a front service area sink with evidence of pests. The presence of insects, rodents, and other pests shall be controlled to minimize their presence on the premises by: 1. Routinely inspecting incoming shipments of food and supplies; 2. Routinely inspecting the premises for evidence of pests; 3. Using methods, if pests are found, such as trapping devices or other means of pest control as specified under subsections (6)(e), (6)(m), and (6)(n) of this Rule; Pf and 4. Eliminating harborage conditions. PIC shall have the facility serviced by a licensed pest control technician. New Violation. Correct By: 03/23/2024
|
|
|
Remarks
|
Emailed report Issued legal notice for no hot water available. Peachtree Pest Control Apex grease Sanitizer: quat —three compartment sink: 300ppm —sanitizer bucket: 200ppm, 300ppm Sanitizer: chlorine —dishwasher: 0ppm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|